PT. Inti Jaya Presisi

sql
Electric Cables Circuit Integrity Burn Test Apparatus IEC 60331 Standard
Electric Cables Circuit Integrity Burn Test Apparatus IEC 60331 Standard
Electric Cables Circuit Integrity Burn Test Apparatus IEC 60331 Standard
Hover to Zoom

Update Terakhir
06 Agt 2020
Negara Asal
Indonesia
Pembelian Min
1 Pieces

Spesifikasi

Fire-resistant cable refers to the cable that can keep a safe running time in the case of flame combustion.
Fire Resistance Tester is designed according to the requirements of IEC60331-11, and used to obtain the refractory characteristics of a fire resistant cable or optical cable under flame conditions.
User' s Experience :
This cabinet is made of stainless steel, anti-smoke and gas corrosion.
The control system is designed with a high degree of automation, automatic ignition, temperature and time digital display, convenient to observe and record, stable and reliable.
International Standards :
- IEC 60331 Tests for electric cables under fire conditions - Circuit Integrity - Procedures and requirement for fire with shock--Cables of rated voltage up to and including 0.6/1 KV
- GB/T 19216 Test for electric or optical fibre cables under fire conditions - Circuit Integrity - Procedures and requirement for fire with shock - Cables of rated voltage up to and including 0.6/1 KV
- BS 6387 Test methods for resistance to fire of cables required to maintain circuit integrity under fire conditions
- BS 8491 Method for assessment of fire integrity of large diameter power cables for use as components for smoke and heat control systems and certain other active fire safety systems
- BS EN 50200 & BS 8434
Combustion System:
1, Independent standard electrical control platform;
2, With intelligent detection function, when a short circuit in the sample during the test, automatic alarm
and turn off the fire source.
3, Fuse current in the experimental circuit is 2A;
4, The sample is applied to power of AV 100V ~ 1000V adjustable;
5, The time can be set free for the fire, the time recommended by standards is 90min.
Device parameters :
Voltage:AC 380V 3-phase, 50 / 60Hz, 30A
Input voltage :0 - 1000 V, can be adjusted
Breakdown current:2 A
Maximum power:5000 VA
Timer:0 - 999 min
Flame temperature :0 - 1100 ÂșC adjustable
Test load current :0.25 A, can be adjusted
Tag : Alat Ukur Lainnya

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Minta Penawaran
Produk Siap di Pesan
Rp 0
1

Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot